SelectYourLanguage

Pulldown 2
Pulldown 2
Pulldown 2
Pulldown 2
Pulldown 2
Pulldown 2
Pulldown 2
Pulldown 2
Pulldown 2

eurocol
501 EUROSTAR TEX PRO

501

Carpet adhesive

501_eurostar tex pro_small.jpg
  • pdf-product-specification.pdf

    pdf-product-specification.pdf

  • safety data sheet_eurocol_501_eurostar_tex_pro_uk.pdf

    safety data sheet_eurocol_501_eurostar_tex_pro_uk.pdf

  • licence_501 tex_ec1plus_2020-uk.pdf

    licence_501 tex_ec1plus_2020-uk.pdf

Product Typification

TODO
Basis : Acrylic dispersion.
Consistency : Thick liquid.

Product advantages:
  • Wet-set adhesive for bonding of carpet floorings with different backing types and light needle felt floorings.
  • For laying on standard-compliant, fully levelled, absorbent subfloors.
  • Suitable over underfloor heating systems.
  • Castor wheel resistant according to DIN EN 12529.
  • Shampoo resistant according to RAL 991 A2.
  • For indoor use only.
  • Very low VOC emission EMICODE EC 1 Plus.
  • Emission-tested construction product according to DIBt principles.

Performances

Consumption : Approx ca. 450 g/m².
Curing : 24 hours.*
Flammability : Non-flammable.
Frost resistance : No.
Specific weight : 1.46 kg/l

Application

Application:

For bonding of:

  • textile coverings with synthetic secondary backing,
  • CV floorings with carrier fleece,
  • light needle fleece.

Working Process

Open time : 5 - 20 minutes.*
Waiting time : None.
Curing : 24 hours.*
Storage : Store cool and free from frost.
Shelf Life : Approx 15 months, in unopened packaging. After use close the open packaging well.
Cleaner : Water.
Frost-proof : No.
Remarks : 

Please pay attention to the technical data sheet and safety data sheet issued by the floor covering manufacturer.
Outside Germany relevant national regulations are to be applied which have to be known by the user.

During the setting time, avoid direct loads of sunshine and heat.
Allow the floor covering to be acclimatized before laying. The laying materials must be relaxed and plane.
In case of installing filler-free, vapour-permeable floor coverings please assure an airing time of approx. 15 minutes. Never install the floor covering into the wet adhesive as the moisture of the adhesive negatively influences the backing of the floor covering!
In case of installing very rigid textile or needle felt floor coverings we recommend running self-made tests or use Eurocol 609 Eurostar Tex.

EMICODE, further information at www.emicode.com.


Wear protective gloves / eye protection.

* The mentioned values have been established in our laboratory and must be considered as guidelines in view of possible variations in climatic circumstances, subfloor compositions and layer thickness.

Consumption:
Approx ca. 450 g/m².

Substrate:
  • The substrate must be pressure- and tension-resistant, permanently dry, free of cracks and dust, even and free of layers that reduce adhesion.
  • Adhesion-reducing layers, old material residues must be removed by suitable mechanical measures in accordance with the specifications of DIN 18365.
  • For levelling the substrate use recommended Eurocol levelling compounds/primers.
  • The installation materials to be used must be suitable for the substrate and the intended use.


User manual:
  • Before use, temper the product according to the processing conditions.
  • Stir before use!
  • Depending on the type of flooring, apply the adhesive with a notched trowel to the subfloor over the entire surface and evenly without adhesive nests. The back of the flooring must be completely wetted with adhesive in scored format. Worn-out spatulas need to be replaced in time to guarantee the minimum adhesive consumption.
  • Coverings must be laid in the adhesive bed which is still wet.
  • The necessary flash-off time depends on the amount of adhesive (toothed strip), temperature, humidity and the absorbency of the subfloor.
    When finger-testing, the adhesive must have a soft centre, must be tacky, pull threads, but must not smear.
  • Depending on the room climate and the absorbency of the substrate, the air-conditioned covering should be pushed into the adhesive bed immediately or after the flash-off time specified in the technical data, rubbed in and rolled on. Air pockets under the covering must be avoided or removed immediately.
  • Head ends and non-flat covering edges must always be rolled in.
  • If necessary, rub or roll the top ends, stove bars, seams or other hollow areas again approx. 15 minutes after installation.

Working conditions: 

At least 15 °C floor temperature,
at least 18°C material and room temperature,
35-75% relative humidity, recommendet <65%.




Quality and guarantee

Environment and health

GISCODE : D1
LEED : VOC 0 g/l, meets: IEQ Credit 4.1
DGNB : VOC 0 %, quality level: 4
Safety and environment : Safety data sheets of Forbo Eurocol products according to EEG-guideline 91/155. Keep out of reach of children. Do not eat, drink or smoke while processing the product. Only give completely empty containers for recycling. Material residues can be disposed of as household waste.
MSDS : Available on request.
Substances causing allergy : Contains reaction mass of: 5-chloro-2-methyl-4-isothiazolin-3-one [EC no. 247-500-7] and 2- methyl-2H-isothiazol-3-one [EC no. 220-239-6] (3:1), 1,2-benzisothiazol-3(2H)-one. May produce an allergic reaction.


Articles

artikelproductnamepackagingshipping unit
501Eurostar Tex ProPE bucket à 14 kg44/pallet